Flow Detector Sensor for NOVAMAX, NOVANOX, and PLATINUM Ref. 125843538
RefurbishedBaxiFlow detectors

Flow Detector Sensor for NOVAMAX, NOVANOX, and PLATINUM Ref. 125843538

Stock · 1 unit

The flow detection sensor for NOVAMAX, NOVANOX, and PLATINUM, reference 125843538 from Baxi, is responsible for detecting the flow of water when a tap is opened and activates the ignition to produce domestic hot water. If it malfunctions, you will notice that hot water does not come out even with the tap open. This component is compatible with models such as NOVAMAX 25/25 F, NOVANOX 24/24 F, and PLATINUM MAX PLUS 24/24 F, among others. It is recommended to replace it when you experience issues obtaining hot water when opening the tap.

VAT included

Compatibility

Baxi boilers compatible with reference 125843538

Flow meter with reference 125843538. 14 verified compatibilities: NOVAMAX 25/25 F and NOVAMAX 31/31 F.

Proven compatibility

Boiler modelFamilyVerification
Baxi NOVAMAX 25/25 FNOVAMAXContrasted
Baxi NOVAMAX 31/31 FNOVAMAXContrasted
Baxi NOVANOX 24/24 FNOVANOXContrasted
Baxi NOVANOX 28/28 FNOVANOXContrasted
Baxi PLATINUM MAX PLUS 24/24 FPLATINUM MAX PLUSContrasted
Baxi PLATINUM MAX PLUS 28/28 FPLATINUM MAX PLUSContrasted
Baxi PLATINUM MAX PLUS 33/33 FPLATINUM MAX PLUSContrasted
Baxi PLATINUM MAX PLUS 40/40 FPLATINUM MAX PLUSContrasted
Baxi PLATINUM COMPACT 24/24 FPLATINUM COMPACTContrasted
Baxi PLATINUM COMPACT 26/26 FPLATINUM COMPACTContrasted
Baxi PLATINUM COMPACT 28/28 FPLATINUM COMPACTContrasted
Baxi PLATINUM COMPACT 30/30 FPLATINUM COMPACTContrasted
Baxi PLATINUM ALUX 24/24 FPLATINUM ALUXContrasted
Baxi PLATINUM ALUX 33/33 FPLATINUM ALUXContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 125843538 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 125843538. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter 125843538 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening a hot water tap, the boiler does not ignite to heat it.

    Cause: The flow sensor does not detect that water is passing through and does not give the command to start the burner for domestic hot water.

    Check the cold water inlet filter: if it is blocked by limescale, the flow rate decreases so much that the sensor does not detect it even if it is working properly.

  • 02

    The hot water cuts off and comes out in bursts, with the temperature rising and falling while in use.

    Cause: The internal moving part of the sensor gets stuck or loses consistency and sends an unstable flow signal to the PCB.

    Check the incoming water supply pressure; if it fluctuates, it can cause the same symptom even if the sensor is not faulty.

  • 03

    The water comes out lukewarm instead of hot when the tap is slightly open.

    Cause: The sensor does not accurately indicate the minimum flow required for the boiler to modulate the flame at the appropriate level.

    Open the tap to maximum flow and observe if the flame rises; if nothing changes, it is advisable to check the gas valve first.

  • 04

    There is a water leak visible on the body of the sensor or around its connector.

    Cause: The internal gasket of the sensor degrades over time and loses tightness in the water passage.

    Dry the area well and turn on the boiler to locate the exact point of the leak before requesting the spare part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Baxi 125843538 flow meter datasheet

Catalogue reference
125843538
Brand
Baxi
Type of part
Flow detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the flow meter 125843538

Does this flow detector sensor work for my NOVAMAX 2525F GN boiler?
Yes, it is on the list of compatible boilers, along with the other NOVAMAX, NOVANOX, and PLATINUM models indicated.
Does it also work for the PLATINUM ALUX 3333F?
Yes, Platinum Alux 3333F is among the compatible models for this part.
How is this flow sensor mounted in the PLATINUM COMPACT 2828F GN boiler?
With a blue connector and a heat-shrinkable label on the cable.

Spare parts related to Baxi PLATINUM MAX PLUS

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model