Flow switch Cointra Excellent D Micro LN 24 E - Ref. C30015300 (code On Part 33900029)
The flow switch detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water. If it fails, hot water will not come out even if the tap is open, which can be indicated by the fault code F43: No circulation in the system. This component is compatible with Cointra models such as Excellent D Micro LN 24 E, Excellent Micro LN 24 E, Essential 24 E, Fer Easy C24, and Domiproject F24, among others. It is recommended to replace it when the symptom of lack of hot water appears or the corresponding fault code is activated.
VAT included
Consult via WhatsAppCointra boilers compatible with reference C30015300
Flow meter with reference C30015300. Five confirmed compatibilities: Excellent D Micro LN 24 E and Excellent Micro LN 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Cointra Excellent D Micro LN 24 E | Cointra Excellent Micro LN | Contrasted |
| Cointra Excellent Micro LN 24 E | Cointra Excellent Micro LN | Contrasted |
| Cointra Essential 24 E | Cointra Essential | Contrasted |
| Cointra Fer Easy C24 | Cointra Fer Easy | Contrasted |
| Cointra Domiproject F24 | Cointra Domiproject | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. C30015300 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference C30015300. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter C30015300 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
When opening the hot water tap, the boiler does not start the burner to heat it.
Cause: The flow switch does not detect the flow of water and does not send the signal to activate the DHW mode.
Check that the water flow when opening the tap is sufficient; with a very low flow rate, the flow switch may not activate.
- 02
It feels like you have to open the tap almost all the way for hot water to come out.
Cause: A pressure switch with a partially obstructed passage requires more flow than usual to activate the contact.
Check if the filter before the pressure switch has scale or dirt buildup before replacing the part.
- 03
The hot water comes in and out, cutting off and returning several times while the tap remains open.
Cause: The flow switch intermittently loses and regains the flow signal, causing the boiler to turn the burner on and off following those interruptions.
Check the pressure of the system on the manometer, because low pressure causes the same effect of interruptions.
- 04
The heating works normally, but the domestic hot water never starts.
Cause: If the flow switch does not close the contact, the boiler never receives the command to activate the DHW mode.
Make sure that the domestic hot water shut-off valve is fully open before replacing the part.
Fault codes for Cointra that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F43 | There is no circulation in the system. | This can happen if the pressure switch is not functioning properly. If there is no water circulation, the boiler will not be able to heat adequately. Check the pressure switch to ensure it is in good condition. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Datasheet for the Cointra C30015300 flow meter
- Catalogue reference
- C30015300
- Brand
- Cointra
- Type of part
- Flow Detectors
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Code engraved on the body
- 33900029
- Batch / date
- 316-14 / 19-A
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Cointra Excellent Micro LN 24 E Manual (PDF)Document © Cointra, provided as a technical reference.