Pressure Gauge 0-4 Bar Cointra Excellent Low NOx - Ref. 39820080
- For 22 Cointra boilers Cointra EXCELLENT Low NOx and Ferroli DIVATECH / DOMITECH
- 0-4 bar
- Check for: The pressure gauge never moves, neither when filling the water nor when bleeding a radiator., Water is dripping from behind, in the area where the pressure gauge connects to the boiler.
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Cointra boilers compatible with reference 39820080
- EXCELLENT MICRO LOW NOX 24ECointra EXCELLENT (Micro) Low NOx
- EXCELLENT MICRO LOW NOX 32ECointra EXCELLENT (Micro) Low NOx
- EXCELLENT MICRO LOW NOX D 24ECointra EXCELLENT (Micro) Low NOx
- EXCELLENT MICRO LOW NOX D 32ECointra EXCELLENT (Micro) Low NOx
- DOMIPROJECT F24Ferroli DOMIPROJECT / DOMICOMPACT
- DOMIPROJECT F32Ferroli DOMIPROJECT / DOMICOMPACT
- DOMIPROJECT D F24Ferroli DOMIPROJECT / DOMICOMPACT
- DOMIPROJECT D F32Ferroli DOMIPROJECT / DOMICOMPACT
- DOMICOMPACT F24Ferroli DOMIPROJECT / DOMICOMPACT
- DOMICOMPACT F30Ferroli DOMIPROJECT / DOMICOMPACT
- DIVATECH F24Ferroli DIVATECH / DOMITECH
- DIVATECH F32Ferroli DIVATECH / DOMITECH
- DIVATECH MICRO F24Ferroli DIVATECH / DOMITECH
- DIVATECH MICRO F32Ferroli DIVATECH / DOMITECH
- DOMITECH C24Ferroli DIVATECH / DOMITECH
- DOMITECH C32Ferroli DIVATECH / DOMITECH
- DOMITECH F24Ferroli DIVATECH / DOMITECH
- DOMITECH F32Ferroli DIVATECH / DOMITECH
- LAMBORGHINI NINFA LOW NOX N24 MCALamborghini / Joannes (same group as Ferroli)
- LAMBORGHINI TAURA D24Lamborghini / Joannes (same group as Ferroli)
- LAMBORGHINI TAURA D32Lamborghini / Joannes (same group as Ferroli)
- JOANNESLamborghini / Joannes (same group as Ferroli)
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. 39820080 is the spare part for your boiler
-
Read the reference on your pressure gauge
It must show 39 820 080 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (pressure gauge 39820080)
The pressure gauge never moves, neither when filling the water nor when bleeding a radiator.
- Cause
- The internal mechanism has become blocked, which is common if dirt has entered through the connection thread.
- What to do
- Fill the water slowly with the filling valve and check if the needle makes at least a small initial jump.
The gauge shows a pressure that doesn't match what you have always seen in that installation.
- Cause
- The mechanism has lost calibration and no longer accurately translates the actual pressure in the reading.
- What to do
- If you have another portable manometer, compare the reading at the same point before replacing the part.
The dial is fogged or broken, and no numbers can be distinguished.
- Cause
- Moisture has entered the body or there is an impact that has damaged the glass.
- What to do
- Look carefully to see if you notice needle movement when touched, even if you can't read the number; it indicates whether the mechanism is still functioning.
Water is dripping from behind, in the area where the pressure gauge connects to the boiler.
- Cause
- The tightness of the thread has been lost, something common over the years and with the cycles of heat.
- What to do
- This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Error codes for Cointra that require diagnosis
Error F37: The water pressure is too low.
- Technical checks
- This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.
Error F40: The water pressure is too high.
- Technical checks
- The water pressure in the system is incorrect and too high. This can cause problems in the system. If the pressure gauge shows excessive pressure, you may need to replace it.
Technical sheet: pressure gauge Cointra 39820080
If you notice that the boiler shows incorrect pressure or temperature readings, a technical diagnosis must confirm whether you need the pressure gauge 0-4 bar Cointra Excellent Low NOx - Ref. 39820080. This part measures and controls the pressure in the boiler circuit, ensuring it operates properly. When it fails, it can cause lockouts due to false low pressure or issues with temperature regulation. It is compatible with Cointra Excellent Low NOx boilers, as well as others like Ferroli Domiproject and Lamborghini. A technician must confirm through diagnosis whether it needs to be replaced when it starts to show erroneous readings or instability in pressure.
Spare part details
- Cointra reference
- 39820080
- Pressure scale
- 0-4 bar
- Country of manufacture
- Italy
Check the reference and label details against the spare part you have installed: two similar references are not always equivalent. Technical sheet reviewed on .
Frequently asked questions about the spare part pressure gauge Cointra 39820080
Does this manometer work for the Cointra Excellent Low NOx 24 E boiler?
Yes, the Cointra Excellent Low NOx 24 E is on the list of compatible boilers in this document.
Is this manometer suitable for the Divatech F32?
Yes, the Divatech F32 is among the compatible boiler models listed in this document, along with other models from the Divatech range.
What pressure does the manometer of the Domiproject F24 measure?
From 0 to 4 bar, according to the printed scale.
When should the manometer of the Domicompact F24 be replaced?
When it stops showing pressure or leaks from the thread.
What is the reference for this manometer?
To confirm compatibility, check the manufacturer's reference and the exact model of the equipment.
How many models are compatible with this manometer?
This pressure gauge is compatible with a total of 22 models.
How do I know if this spare part (pressure gauge) 39820080 is the right one for my Cointra boiler?
Look at the reference printed on the installed spare part (pressure gauge): it should read 39 820 080. Then check the model on your boiler’s rating plate. This spare part (pressure gauge) has 22 verified compatibilities, in the families Cointra EXCELLENT (Micro) Low NOx, Ferroli DOMIPROJECT / DOMICOMPACT, Ferroli DIVATECH / DOMITECH and Lamborghini / Joannes (mismo grupo Ferroli). If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (pressure gauge) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part pressure gauge, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.