Ferroli Divatop F24 Air Pressure Switch Huba Control Ref. 401.93000 Ref. I39828420
- For 13 Ferroli boilers Ferroli SUN P and Ferroli Ferdigit
- 12VDC (10.4-18VDC) · 0...+3 mbar
- Check for: The boiler does not ignite the burner, although the fan is working., The display shows a fault warning for the air sensor.
- Out of stock for now: we will notify you when it is back
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Ferroli boilers compatible with reference I39828420
- Excellent Micro Low NOx 24ECointra Excellent Micro Low NOx
- Excellent Micro Low NOx D 24ECointra Excellent Micro Low NOx
- Divatop F24Ferroli Divatop / Divatop Low NOx / Divatop Micro
- Divatop F32Ferroli Divatop / Divatop Low NOx / Divatop Micro
- Divatop Low NOx F24Ferroli Divatop / Divatop Low NOx / Divatop Micro
- Divatop Low NOx F32Ferroli Divatop / Divatop Low NOx / Divatop Micro
- Divatop Micro F24Ferroli Divatop / Divatop Low NOx / Divatop Micro
- Divatop Micro F32Ferroli Divatop / Divatop Low NOx / Divatop Micro
- Divatop Micro LNFerroli Divatop / Divatop Low NOx / Divatop Micro
- SUN P7Ferroli SUN P
- SUN P12Ferroli SUN P
- Ferdigit F24Ferroli Ferdigit
- Ferdigit Micro F24Ferroli Ferdigit
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if Ref. I39828420 is the spare part for your boiler
-
Read the reference on your pressure switch
It must show I39828420 on the label or the screen print. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (pressure switch I39828420)
The boiler does not ignite the burner, although the fan is working.
- Cause
- The sensor does not send the correct signal to the control board, which cuts off the ignition.
- What to do
- Check that the sensor connector is properly tightened and dry before considering it faulty.
The extractor works, but the boiler does not proceed to the ignition phase.
- Cause
- The control board does not allow gas valve operation without a valid pressure reading from the sensor.
- What to do
- Check that the extractor is operating at its normal speed; a slow extractor can give an incorrect pressure reading.
The display shows a fault warning for the air sensor.
- Cause
- The control board indicates that the pressure sensor reading is not valid.
- What to do
- Check that the silicone tubes carrying pressure to the sensor are in good condition and free of obstructions.
The boiler sometimes ignites and other times it gets stuck during startup.
- Cause
- A sensor with unstable readings can send signals that are not consistent.
- What to do
- Make several attempts to ignite and check the electrical connection of the sensor before considering replacing it.
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Error codes for Ferroli that require diagnosis
Error F05: The air pressure switch does not close.
- Technical checks
- The air pressure switch is not functioning properly and is not closing the contacts. This may be caused by a fault in the pressure switch itself or by obstructions in the air outlet. Check the condition of the pressure switch and ensure that there are no obstructions in the ventilation.
Error F07: The air pressure switch is activated.
- Technical checks
- The air pressure switch contacts remain closed when the fan is activated. This may indicate a problem in the ventilation system. Make sure the fan is working properly and check the condition of the pressure switch.
Technical sheet: pressure switch Ferroli I39828420
Air pressure sensor Huba Control (code 401.93000), used in Ferroli Divatop, Divatop Micro, Sun boilers and in Joannes and Lamborghini models. Powered at 12VDC, it delivers an analog signal of 0.5 to 4.5V proportional to the measured pressure, between 0 and +3 mbar, with a maximum allowable of 25 mbar. The replacement requires first confirming the fault of the part through technical diagnosis, even when that reading fails and the boiler locks out due to air pressure.
Spare part details
- Ferroli reference
- I39828420
- Operating pressure range
- 0...+3 mbar
- Maximum pressure
- 25 mbar
- Output signal
- 0.5-4.5V RL>15kOhm
- Component code
- 401.93000
- Supply voltage
- 12VDC (10.4-18VDC)
Check the reference and label details against the spare part you have installed: two similar references are not always equivalent. Technical sheet reviewed on .
Frequently asked questions about the spare part pressure switch Ferroli I39828420
Is the pressure sensor 401.93000 of the Ferroli Divatop F24 mechanical or electronic?
It is an electronic sensor Huba Control with an analog output of 0.5 to 4.5V, powered at 12VDC.
What boiler models are compatible with the Huba Control 401.93000 air pressure switch?
This pressure switch is compatible with 13 models from the Cointra Excellent Micro Low NOx, Ferroli Divatop, Ferroli SUN P, and Ferroli Ferdigit ranges.
What pressure does the sensor of the Ferroli Divatop F32 measure?
It measures from 0 to +3 mbar, with a maximum allowable pressure of 25 mbar.
What fault codes can occur with this sensor?
The documented fault codes are F05 and F07.
What is the reference to order the Huba Control pressure sensor?
To confirm compatibility, check the manufacturer's reference and the exact model of the equipment.
How do I know if this spare part (pressure switch) I39828420 is the right one for my Ferroli boiler?
Look at the reference printed on the installed spare part (pressure switch): it should read I39828420. Then check the model on your boiler’s rating plate. This spare part (pressure switch) has 13 verified compatibilities, in the families Cointra Excellent Micro Low NOx, Ferroli Divatop / Divatop Low NOx / Divatop Micro, Ferroli SUN P and Ferroli Ferdigit. If you cannot find the reference or your model is not on the list, send us a photo via WhatsApp and we will confirm it before you buy.
What does it mean that this spare part (pressure switch) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part pressure switch, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.
Out of stock. How will I know when it is back in stock?
Click “Book” and leave your email: we will contact you as soon as a unit is available. Signing up is free of charge.