Ferroli Divatop F24 Air Pressure Switch Huba Control Ref. 401.93000
RefurbishedFerroliPressure switchesHuba Control

Ferroli Divatop F24 Air Pressure Switch Huba Control Ref. 401.93000

Stock · 1 unit

Huba Control air pressure sensor (code 401.93000), used in Ferroli Divatop, Divatop Micro, Sun boilers and in Joannes and Lamborghini models. Powered at 12VDC, it delivers an analog signal of 0.5 to 4.5V proportional to the measured pressure, between 0 and +3 mbar, with a maximum allowable of 25 mbar. It is replaced when that reading fails and the boiler locks out due to air pressure.

VAT included

Compatibility

Ferroli boilers compatible with reference I39828420

Pressure switch with reference I39828420. 13 verified compatibilities: Excellent Micro Low NOx 24E and Excellent Micro Low NOx D 24E.

Proven compatibility

Boiler modelFamilyVerification
Ferroli Excellent Micro Low NOx 24ECointra Excellent Micro Low NOxContrasted
Ferroli Excellent Micro Low NOx D 24ECointra Excellent Micro Low NOxContrasted
Ferroli Divatop F24Ferroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli Divatop F32Ferroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli Divatop Low NOx F24Ferroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli Divatop Low NOx F32Ferroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli Divatop Micro F24Ferroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli Divatop Micro F32Ferroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli Divatop Micro LNFerroli Divatop / Divatop Low NOx / Divatop MicroContrasted
Ferroli SUN P7Ferroli SUN PContrasted
Ferroli SUN P12Ferroli SUN PContrasted
Ferroli Ferdigit F24Ferroli FerdigitContrasted
Ferroli Ferdigit Micro F24Ferroli FerdigitContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. I39828420 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference I39828420. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch I39828420 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite the burner, although the fan is working.

    Cause: The sensor does not send the correct signal to the control board, which cuts off the ignition.

    Check that the sensor connector is properly tightened and dry before considering it faulty.

  • 02

    The display shows a fault warning for the air sensor.

    Cause: The control board indicates that the pressure sensor reading is not valid.

    Check that the silicone tubes carrying pressure to the sensor are in good condition and free of obstructions.

  • 03

    The extractor works, but the boiler does not proceed to the ignition phase.

    Cause: The control board does not allow gas valve operation without a valid pressure reading from the sensor.

    Check that the extractor is operating at its normal speed; a slow extractor can give an incorrect pressure reading.

  • 04

    The boiler sometimes ignites and other times it gets stuck during startup.

    Cause: A sensor with unstable readings can send signals that are not consistent.

    Make several attempts to ignite and check the electrical connection of the sensor before considering replacing it.

Fault codes for Ferroli that this part resolves.

CodeFaultDiagnosis and solution
F05The air pressure switch does not close.The air pressure switch is not functioning properly and is not closing the contacts. This may be caused by a fault in the pressure switch itself or by obstructions in the air outlet. Check the condition of the pressure switch and ensure that there are no obstructions in the ventilation.
F07The air pressure switch is activated.The air pressure switch contacts remain closed when the fan is activated. This may indicate a problem in the ventilation system. Make sure the fan is working properly and check the condition of the pressure switch.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Ferroli pressure switch I39828420

Catalogue reference
I39828420
Brand
Ferroli
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Supply voltage
12VDC (10.4-18VDC)
Operating pressure range
0...+3 mbar
Maximum pressure
25 mbar
Output signal
0.5-4.5V RL>15kOhm
Component code
401.93000
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch I39828420

Is the pressure sensor 401.93000 of the Ferroli Divatop F24 mechanical or electronic?
It is an electronic sensor Huba Control with an analog output of 0.5 to 4.5V, powered at 12VDC.
What boiler models are compatible with the Huba Control 401.93000 air pressure switch?
This pressure switch is compatible with 13 models from the Cointra Excellent Micro Low NOx, Ferroli Divatop, Ferroli SUN P, and Ferroli Ferdigit ranges.
What pressure does the sensor of the Ferroli Divatop F32 measure?
It measures from 0 to +3 mbar, with a maximum allowable pressure of 25 mbar.
What fault codes can occur with this sensor?
The documented fault codes are F05 and F07.
What is the reference to order the Huba Control pressure sensor?
The reference to request it is PCDNOXF24.