Junkers Air Pressure Switch ZWSB 22/28-3, ZWSE 24-5 MFA and MFK Huba Control Ref. 8716771261
RefurbishedJunkersPressure switchesHuba Control

Junkers Air Pressure Switch ZWSB 22/28-3, ZWSE 24-5 MFA and MFK Huba Control Ref. 8716771261

Stock · 1 unit

Differential air pressure switch, part code 605.99550 and reference 8716771261 according to the label, for Junkers boilers ZWSB 22/28-3, ZWSE 24-5 MFA, and ZWSE 24-5 MFK. It detects the air pressure difference in the flue/fan circuit and shuts down the operation if it is not correct, preventing the boiler from starting without safe combustion. It is replaced when there is an air pressure or fan error.

VAT included

Compatibility

Junkers boilers compatible with reference 87167715800

Pressure switch with reference 87167715800. Two confirmed compatibilities: ZWC 28/32-1MFA 23 and ZWC28-1MF2A 23.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWC 28/32-1MFA 23Junkers Euromaxx ZWCContrasted
Junkers ZWC28-1MF2A 23Junkers Euromaxx ZWCContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87167715800 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87167715800. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 87167715800 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start and locks out showing an air pressure or fan fault.

    Cause: The differential pressure switch does not detect the pressure difference generated by the fan and does not allow the ignition.

    Check that the fan starts and sounds normal before assuming that the pressure switch is the problem.

  • 02

    An error code related to the pressure switch or the flue fan appears on the screen.

    Cause: The PCB associates that code with not receiving the correct pressure confirmation from the pressure switch.

    Note the exact code and consult the fault manual of the boiler before purchasing, to rule out that it is the fan.

  • 03

    The ignition attempts fail one after another, without the flame igniting.

    Cause: Being a differential pressure switch, it needs to measure pressure at two points simultaneously; if one of the tubes fails, it will never provide the correct signal.

    Check both connection tubes of the pressure switch, not just one, in case one is disconnected, crushed, or has water inside.

  • 04

    The boiler works well for a few days and then starts to intermittently lock out due to the same fault.

    Cause: The pressure switch contact may start to fail gradually before completely stopping functioning.

    Keep a record of when the fault occurs, in cold conditions, with wind, or after prolonged use, as it helps to confirm if the pattern fits a faulty pressure switch.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
C4The pressure switch does not open in the rest position.The air differential pressure switch remains closed at rest due to an internal fault or water/dirt in the tubes, so the control board "sees" it as activated; check continuity at rest with a multimeter and inspect/clean tubes and venturi inlets.
C6The pressure switch does not close.With the fan running, the pressure differential is not reached, or the pressure switch (membrane/micro) fails and does not close; check closure by applying vacuum with a vacuum gauge or acting on the connection while measuring continuity, and inspect tubes, venturi, and extractor.
C1The pressure switch has activated during operation.During full combustion, the pressure switch opens due to an internal fault or a momentary loss of depression in the air/flue circuit; check the stability of the contact by measuring continuity during the cycle and inspect silicone tubes, venturi, and condensate drain.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Junkers pressure switch 87167715800

Catalogue reference
87167715800
Brand
Junkers
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Part code
605.99550
Reference (corrected)
8716771261 (printed as '8-716-771-261')
Differential pressure
55/45 Pa
Current / voltage
1(0.5) A / 250 V~
Batch
KRTAEE
Frequently Asked Questions

Frequently asked questions about the pressure switch 87167715800

What is the correct reference for the pressure switch of the Junkers ZWSB 22/28-3?
8716771261, according to the part label; the reference previously published in the store (87167715800) was incorrect.
Does Huba Control manufacture the pressure switch for the Junkers ZWSE 24-5 MFA?
Yes, regarding the reference, although it is not printed as such on the label of this unit.
Is it an air pressure switch or a water pressure switch that the Junkers ZWSE 24-5 MFK uses?
Air; the pressure values on the label are in pascals (Pa), typical for this type of pressure switch.
What fault indicates that the pressure switch of the Junkers ZWSB 22/28-3 needs to be replaced?
It is replaced when the boiler shows an air pressure or fan fault.
What is the differential pressure of the pressure switch for the Junkers ZWSE 24-5 MFA?
55/45 Pa, according to the label.
What is the part code for the pressure switch of the Junkers ZWSE 24-5 MFK?
Part code 605.99550 and reference 8716771261, according to the label.

Spare parts related to Junkers Junkers Euromaxx ZWC

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Junkers Air Pressure Switch ZWSB 22/28-3, ZWSE 24-5 MFA and MFK Huba Control Ref. 8716771261