CIMM RP250 Expansion Vessel For Ferroli Bluehelix PRO 32C Ref. 39846070
Membrane expansion vessel manufactured by CIMM (model RP250 according to the label), with a capacity of 10 liters and a pre-charge pressure of 0.8 bar. It absorbs the expansion of water in the heating circuit and maintains stable pressure. It is replaced when it loses pre-charge, leaks, or the boiler frequently needs repressurization.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference 39846070
Expansion vessel with reference 39846070. Nine confirmed compatibilities: Bluehelix Pro 25C and Bluehelix Pro 32C.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Bluehelix Pro 25C | Ferroli | Contrasted |
| Ferroli Bluehelix Pro 32C | Ferroli | Contrasted |
| Ferroli Bluehelix Pro S 27C | Ferroli | Contrasted |
| Ferroli Bluehelix Tech 25C | Ferroli | Contrasted |
| Ferroli Bluehelix Tech 35C | Ferroli | Contrasted |
| Ferroli Bluehelix Tech 18A | Ferroli | Contrasted |
| Ferroli Bluehelix Tech 25A | Ferroli | Contrasted |
| Ferroli Bluehelix Tech 35A | Ferroli | Contrasted |
| Ferroli Superlative Condens 25C | Ferroli | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 39846070 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39846070. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the expansion vessel 39846070 resolves.
The expansion vessel absorbs the expansion of water when heated. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You need to add pressure to the heating circuit more often than usual.
Cause: The vessel is losing air and cannot compensate for the expansion of the water, which causes the pressure to drop on its own.
With the boiler cold and without pressure in the circuit, check the valve of the expansion vessel to see if it maintains air pressure; if little or nothing comes out, that is the problem.
- 02
Water is coming out of the safety valve after a period of operation of the heating system.
Cause: If the membrane is not in good condition, the vessel cannot absorb the increase in volume of the hot water, which causes the pressure to rise and opens the gas valve.
Observe if the dripping occurs when the water is hot and stops when it cools down; that pattern indicates a problem in the expansion vessel, not in the gas valve.
- 03
There are knocks or noises in the pipes when the pump stops.
Cause: A vessel without air does not dampen the pressure spikes in the circuit, and these are felt as knocks.
Make sure that the shut-off valves are fully open and that there is no air in the radiators.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Ferroli Expansion Vessel Datasheet 39846070
- Catalogue reference
- 39846070
- Brand
- Ferroli
- Type of part
- Expansion vessels
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- model
- RP250
- capacity
- 10 liters
- Pre-charge pressure
- 0.8 bar
- Service temperature
- +90°C / -10°C
- Maximum pressure PS
- 3.0 bar
- Test pressure PT
- 4.3 bar
- CE Directive
- 97/23/EC, EN13831, Category Art.3 Par.3, Fluid Group 2
- Manufacturer address
- CIMM S.p.A., Via Caprera 13, Castello di Godego (TV), Italy
- DIN certco
- 5C033/09