Pressure Gauge Boiler Meteo / Super Exclusive 24 CSI - Ref. R1857

Pressure Gauge Boiler Meteo / Super Exclusive 24 CSI - Ref. R1857

Stock · 1 unit

If your boiler does not regulate the temperature properly or shows incorrect pressure readings, you may need a new pressure gauge for the Meteo / Super Exclusive 24 CSI boiler. This part measures and controls the pressure of the circuit, ensuring proper operation. When it fails, it can cause lockouts due to false low pressure, affecting the performance of the boiler. It is compatible with models such as Super Exclusive Eco Mix 24 CSI, Super Exclusive Mix 26 CSI, and Meteo Mix 28 CSI, among others. It should be replaced when the readings are incorrect or when regulation issues arise.

VAT included

Compatibility

Beretta boilers compatible with reference R1857

Pressure gauge with reference R1857. Eight confirmed compatibilities: Super Exclusive Eco Mix 24 CSI and Super Exclusive Eco Mix 28 CSI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Super Exclusive Eco Mix 24 CSIBeretta Super Exclusive Eco Mix / EcomixContrasted
Beretta Super Exclusive Eco Mix 28 CSIBeretta Super Exclusive Eco Mix / EcomixContrasted
Beretta Super Exclusive Mix 26 CSIBeretta Super Exclusive MixContrasted
Beretta Super Exclusive 24 CSIBeretta Super ExclusiveContrasted
Beretta Super Exclusive 28 CSIBeretta Super ExclusiveContrasted
Beretta Meteo 24 CAIBeretta Meteo / Meteo MixContrasted
Beretta Meteo Mix 24 CSIBeretta Meteo / Meteo MixContrasted
Beretta Meteo Mix 28 CSIBeretta Meteo / Meteo MixContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number R1857 is the one for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R1857. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the R1857 manometer resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The needle never moves, whether the boiler is cold or after heating.

    Cause: The pressure gauge mechanism is stuck or the connection pipe to the circuit is blocked.

    Let the boiler heat up for a while and see if the needle rises a bit, even if it's just a little, before giving up on it.

  • 02

    The pressure indicated by the manometer does not match what the boiler actually does in practice.

    Cause: If the small tube connecting it to the circuit is partially blocked, the needle remains fixed at an old value.

    Fill the circuit to the usual cold pressure and check if the needle rises before changing the part.

  • 03

    There is a water leak right at the thread where the pressure gauge is screwed in.

    Cause: The sealing gasket of the fitting dries out or wears down over time.

    Dry the area well and check again when cold; sometimes the leak comes from a nearby pipe and not from the pressure gauge.

  • 04

    The gauge is broken or so fogged that the pressure scale cannot be read.

    Cause: A blow during handling or the entry of moisture through a deteriorated joint renders the glass unusable.

    Check if the fog disappears by cleaning the outside; if it remains foggy, it means that water has entered inside and there is no solution.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta R1857 pressure gauge.

Catalogue reference
R1857
Brand
Beretta
Type of part
Pressure gauges & aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Part reference
R1857
Pressure gauge
0-4 bar
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the R1857 pressure gauge

Is this pressure gauge Ref. R1857 compatible with the Super Exclusive 24 CSI and the Meteo 24 CAI?
Yes, both boilers are on the list of models compatible with this part, along with other models from the Super Exclusive and Meteo ranges.
What pressure scale does the manometer of the Meteo Mix 24 CSI have?
According to the photographed gauge, it measures from 0 to 4 bar.
Is the reference R1857 engraved on the part of the Super Exclusive 26 CSI?
Yes, the code R1857 is marked on the part itself.
When is it advisable to replace the manometer of the Meteo 24 CAI?
When the needle gets stuck, it shows an incorrect reading or leaks from the connection fitting.
How many models are compatible with the pressure gauge of the Meteo / Super Exclusive 24 CSI boiler?
The pressure gauge is compatible with a total of 8 models.
What is the reference for the pressure gauge for the Meteo and Super Exclusive?
The reference for the pressure gauge is MPEE24CSI.

Spare parts related to Beretta Beretta Meteo / Meteo Mix

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model