Vaillant TurboTEC plus and Turbomax plus incorporate the Vaillant VC 105/2 E display module, a control PCB that manages the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler does not start, locks out, or exhibits erratic operation. You may notice the fault by the F.70 code, which indicates a communication problem between the display and the PCB. This module is compatible with models such as the VMW 24/282-5 and VMW 28/362-5, among others. It is recommended to replace it if you experience these symptoms.

VAT included

Compatibility

Vaillant boilers compatible with reference 130822

PCB with reference 130822. Six confirmed compatibilities: VMW 24/282-5 R1 and VMW 24/282-5 R2.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VMW 24/282-5 R1Vaillant TurboTEC plus / Turbomax plus (VMW 24/282-5)Contrasted
Vaillant VMW 24/282-5 R2Vaillant TurboTEC plus / Turbomax plus (VMW 24/282-5)Contrasted
Vaillant VMW 24/282-5 R3Vaillant TurboTEC plus / Turbomax plus (VMW 24/282-5)Contrasted
Vaillant VMW 24/282/3-5Vaillant TurboTEC plus / Turbomax plus (VMW 24/282-5)Contrasted
Vaillant VMW 24/280-5 R3Vaillant TurboTEC plus / Turbomax plus (VMW 24/282-5)Contrasted
Vaillant VMW 28/362-5 R3Vaillant (VMW 28/362-5)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 130822 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 130822. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 130822 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display does not turn on and remains completely black, although the boiler continues to heat.

    Cause: The display block may fail without affecting the burner circuit, even though they are on the same PCB.

    Check if the water is coming out hot and the radiators are heating; if so, with the screen off, the fault is probably in the display itself.

  • 02

    The heating or radiator icon never appears on the screen, even though the boiler is heating.

    Cause: The icons and temperature are generated by this module; if a segment or icon fails, only that information is lost without affecting the rest of the operation.

    Check if the rest of the display (temperature, other icons) is functioning normally; a partial failure usually confirms that it is the module and not the general power supply.

  • 03

    The display shows the temperature but remains frozen, without updating or blinking the operation symbol.

    Cause: The module receives constant data from the PCB; if the display freezes, the information stops refreshing even though the boiler continues to operate.

    Try a full power off and on of the boiler (not just standby) to see if the display recovers before replacing it.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.70Fault: Invalid appliance code (DSN).This occurs when both the display screen and the main PCB are replaced simultaneously without reprogramming the device identification; the new screen does not match the electronics. Verify by entering d.93 and adjusting the model DSN; also check the resistance/coding.
withNo communication with the main PCB (communication error display ↔ PCB).The display board is not connected or is defective and does not communicate with the main PCB. Check the harness/connector between the display and the board, continuity of wiring, and, if possible, test with another compatible screen.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 130822 PCB.

Catalogue reference
130822
Brand
Vaillant
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 130822

Is this Vaillant VC 105/2 E display module – Ref. 130822 compatible with my Vaillant VMW 282/2-5 boiler?
Yes, it is on the list of boilers compatible with the reference DCVMW362R3.
What does the '13°' mean that appears in the photo of the boiler module?
It's just the temperature reading on the display at the time of the photo, not an identification detail of the part.
Which Vaillant boilers is the Vaillant VC 105/2 E display module compatible with?
It is compatible with the models VMW 24/282-5 R1, VMW 24/282-5 R2, VMW 24/282-5 R3, VMW 24/282/3-5, VMW 24/280-5 R3, and VMW 28/362-5 R3.
What fault codes are documented for this display module?
The documented fault codes are F.70, with.
How many boiler models are compatible with this display module?
A total of 6 models are compatible.